37 Tubing Membrane Modules are designed for separation,concentration and purification of the components of liquid mixtures and waste waters (solutions of high-molecular substances and colloidal solutions, finely divided suspensions, oily wastewater, low-coalescing emulsions). They are perfectly suited for treating solutions containing particles and high viscous solutions or solutions becoming viscous during treatment.
PRODUCT DESCRIPTION | Material | PVDF ( F-100 & F-500) |
Membrane Style | Hollow Membrane ( F-100 & F-500) |
DATA SHEET | Configuration | Polysulfone housing, 37 Root diameter 1/2 Inch tube |
Application | Liquid Filter |
MWCO | F-100 | 150000 Dalton |
F-500 | 250000 Dalton |
SPECIFICATIONS | Number | Model | Effective membrane area(m2) | Water Flux (L/m2h) |
PRODUCTS DETAIL | EFT0705312 | EFT-0412-PU-F-100 | 5.1 | 300 |
EFT0705318 | EFT-0412-PU-F-500 | 5.1 | 600 |
OPERATION INFORMATION | Maximum operating pressure | 6.2 Bar at 49 |
Max. concentration outlet pressure | 0.7 Bar |
High osmoticpressure | 0.2 Bar |
| Single membrane tube inside the General pressure drop | 0.27-0.4 Bar |
Operating parameters | Single membrane tube inside the Max. pressure difference | 0.4 Bar at 49 |
Max. operating pressure | Continue 49 |
| Short term 54 |
pH Value range of use | Continue 2-10 |
| Short term 1.5-10.5 |
Max. resistance of chlorine | 200ppm at pH 10-10.5 at 49 |
We can produce module to replace KOCH, PCI products.